MCS1806 Hall-effect Current Sensors

Monolithic Power Systems (MPS) MCS1806 Hall-effect Current Sensors are 3kVRMS isolated current sensors with 500VRMS working voltage and ±2.5% accuracy. These linear Hall-effect current sensors for AC or DC current sensing incorporate differential Hall arrays that cancel out any stray magnetic fields. The MCS1806 current sensors feature ±5A to ±50A bidirectional range, adjustable bandwidth up to 100kHz, and ratio-metric outputs from the supply voltages. These Hall-effect sensors are available in SOIC-8 packages, which are factory-trimmed for accuracy and offer no magnetic Hysteresis. The MCS1806 Hall-effect current sensors are ideally used in multi-phase inverters, motor controls, automotive systems, Switch-Mode Power Supplies (SMPSs), over-current fault protection, and load detection and management.

결과: 24
선택 이미지 부품 번호 제조업체 설명 데이터시트 구매 가능 정보 가격 (KRW) 수량에 따라 단가별로 테이블의 결과를 필터링합니다. 수량 RoHS ECAD 모델 전류 정격 센서 타입 응답 시간 정확성 주파수 범위 작동 공급 전압 출력 타입
Monolithic Power Systems (MPS) 보드 탑재 전류 센서 3.3V Hall current sensor. 2.5% accuracy. 3kV Isolation 2,260재고 상태
최소: 1
배수: 1
: 2,500

5 A Current Sense 5 us 2.5 % 100 kHz 3.3 V Analog
Monolithic Power Systems (MPS) 보드 탑재 전류 센서 3.3V Hall current sensor. 2.5% accuracy. 3kV Isolation 2,126재고 상태
최소: 1
배수: 1
: 2,500

10 A Current Sense 5 us 2.5 % 100 kHz 3.3 V Analog
Monolithic Power Systems (MPS) 보드 탑재 전류 센서 3.3V Hall current sensor. 2.5% accuracy. 3kV Isolation 871재고 상태
최소: 1
배수: 1
: 500

30 A Current Sense 5 us 2.5 % 100 kHz 3.3 V Analog
Monolithic Power Systems (MPS) 보드 탑재 전류 센서 3.3V Hall current sensor. 2.5% accuracy. 3kV Isolation 2,458재고 상태
최소: 1
배수: 1
: 500

40 A Current Sense 5 us 2.5 % 100 kHz 3.3 V Analog
Monolithic Power Systems (MPS) 보드 탑재 전류 센서 5V Hall current sensor. 2.5% accuracy. 3kV Isolation 685재고 상태
최소: 1
배수: 1
: 500

5 A Current Sense 5 us 2.5 % 100 kHz 5 V Analog
Monolithic Power Systems (MPS) 보드 탑재 전류 센서 5V Hall current sensor. 2.5% accuracy. 3kV Isolation 990재고 상태
최소: 1
배수: 1
: 500

30 A Current Sense 5 us 2.5 % 100 kHz 5 V Analog
Monolithic Power Systems (MPS) 보드 탑재 전류 센서 3.3V Hall current sensor. 2.5% accuracy. 3kV Isolation 348재고 상태
최소: 1
배수: 1
: 500

5 A Current Sense 5 us 2.5 % 100 kHz 3.3 V Analog
Monolithic Power Systems (MPS) 보드 탑재 전류 센서 3.3V Hall current sensor. 2.5% accuracy. 3kV Isolation 380재고 상태
500예상 2026-04-23
최소: 1
배수: 1
: 500

10 A Current Sense 5 us 2.5 % 100 kHz 3.3 V Analog
Monolithic Power Systems (MPS) 보드 탑재 전류 센서 3.3V Hall current sensor. 2.5% accuracy. 3kV Isolation 102재고 상태
500예상 2026-04-23
최소: 1
배수: 1
: 500

20 A Current Sense 5 us 2.5 % 100 kHz 3.3 V Analog
Monolithic Power Systems (MPS) 보드 탑재 전류 센서 3.3V Hall current sensor. 2.5% accuracy. 3kV Isolation 570재고 상태
최소: 1
배수: 1
: 500

50 A Current Sense 5 us 2.5 % 100 kHz 3.3 V Analog
Monolithic Power Systems (MPS) 보드 탑재 전류 센서 5V Hall current sensor. 2.5% accuracy. 3kV Isolation 174재고 상태
최소: 1
배수: 1
: 500

20 A Current Sense 5 us 2.5 % 100 kHz 5 V Analog
Monolithic Power Systems (MPS) 보드 탑재 전류 센서 5V Hall current sensor. 2.5% accuracy. 3kV Isolation 337재고 상태
최소: 1
배수: 1
: 500

40 A Current Sense 5 us 2.5 % 100 kHz 5 V Analog
Monolithic Power Systems (MPS) 보드 탑재 전류 센서 5V Hall current sensor. 2.5% accuracy. 3kV Isolation 387재고 상태
최소: 1
배수: 1
: 500

50 A Current Sense 5 us 2.5 % 100 kHz 5 V Analog
Monolithic Power Systems (MPS) 보드 탑재 전류 센서 5V Hall current sensor. 2.5% accuracy. 3kV Isolation 611재고 상태
최소: 1
배수: 1
: 500

10 A Current Sense 5 us 2.5 % 100 kHz 5 V Analog
Monolithic Power Systems (MPS) 보드 탑재 전류 센서 3.3V Hall current sensor. 2.5% accuracy. 3kV Isolation 비재고 리드 타임 18 주
최소: 1
배수: 1
: 2,500

20 A Current Sense 5 us 2.5 % 100 kHz 3.3 V Analog
Monolithic Power Systems (MPS) 보드 탑재 전류 센서 3.3V Hall current sensor. 2.5% accuracy. 3kV Isolation 비재고 리드 타임 18 주
최소: 2,500
배수: 2,500
: 2,500

30 A Current Sense 5 us 2.5 % 100 kHz 3.3 V Analog
Monolithic Power Systems (MPS) 보드 탑재 전류 센서 3.3V Hall current sensor. 2.5% accuracy. 3kV Isolation 비재고 리드 타임 18 주
최소: 2,500
배수: 2,500
: 2,500

40 A Current Sense 5 us 2.5 % 100 kHz 3.3 V Analog
Monolithic Power Systems (MPS) 보드 탑재 전류 센서 3.3V Hall current sensor. 2.5% accuracy. 3kV Isolation 비재고 리드 타임 18 주
최소: 1
배수: 1
: 2,500

50 A Current Sense 5 us 2.5 % 100 kHz 3.3 V Analog
Monolithic Power Systems (MPS) 보드 탑재 전류 센서 5V Hall current sensor. 2.5% accuracy. 3kV Isolation 비재고 리드 타임 18 주
최소: 2,500
배수: 2,500
: 2,500

5 A Current Sense 5 us 2.5 % 100 kHz 5 V Analog
Monolithic Power Systems (MPS) 보드 탑재 전류 센서 5V Hall current sensor. 2.5% accuracy. 3kV Isolation 비재고 리드 타임 18 주
최소: 2,500
배수: 2,500
: 2,500

10 A Current Sense 5 us 2.5 % 100 kHz 5 V Analog
Monolithic Power Systems (MPS) 보드 탑재 전류 센서 5V Hall current sensor. 2.5% accuracy. 3kV Isolation 비재고 리드 타임 18 주
최소: 2,500
배수: 2,500
: 2,500

20 A Current Sense 5 us 2.5 % 100 kHz 5 V Analog
Monolithic Power Systems (MPS) 보드 탑재 전류 센서 5V Hall current sensor. 2.5% accuracy. 3kV Isolation 비재고 리드 타임 18 주
최소: 2,500
배수: 2,500
: 2,500

30 A Current Sense 5 us 2.5 % 100 kHz 5 V Analog
Monolithic Power Systems (MPS) 보드 탑재 전류 센서 5V Hall current sensor. 2.5% accuracy. 3kV Isolation 비재고 리드 타임 18 주
최소: 2,500
배수: 2,500
: 2,500

40 A Current Sense 5 us 2.5 % 100 kHz 5 V Analog
Monolithic Power Systems (MPS) 보드 탑재 전류 센서 5V Hall current sensor. 2.5% accuracy. 3kV Isolation 비재고 리드 타임 18 주
최소: 2,500
배수: 2,500
: 2,500

50 A Current Sense 5 us 2.5 % 100 kHz 5 V Analog